Changes in anterior chamber eye during accommodation as assessed using a Dual Scheimpflug system

2014

Purpose: To study the changes in anterior chamber depth (ACD), anterior chamber angle (ACA), and pupil diameter (PD) during accommodation. Methods: Eighty eyes of 80 subjects, aged 22 to 40 years, were included. The rotating Dual Scheimpflug and a Placido disc system (Galilei G4, Ziemer Ophthalmic Systems AG, Switzerland) was used to measure the changes in ACD, ACA, and PD during accommodation. ACD measurement was taken for the central zone and for 4 more positions, each in different orientation (nasal, superior, temporal and inferior), 4 mm away from the centre. ACA was measured for the whole eye as well for the nasal, superior, temporal, and inferior quadrants. These metrics were obtained…

AdultMalemedicine.medical_specialtyAnterior ChamberScheimpflug principlePupil diameterIrisVergenceDiagnostic Techniques OphthalmologicalPupilAnterior chamber angleNear visionAnterior chamber eyeYoung AdultOpticslcsh:OphthalmologyOphthalmologyPhotographyMedicineHumansskin and connective tissue diseasesPupilaAnterior chamberCâmara anteriorTécnicas medidas equipamentos de mediçãobusiness.industryAccommodation OcularPupilGeneral Medicineeye diseasesOphthalmologyAcomodação ocularlcsh:RE1-994Accommodation ocularTechniques measures measurement equipmentFemalesense organsbusinessAccommodationTomography Optical CoherenceArquivos Brasileiros de Oftalmologia
researchProduct

Device interchangeability on anterior chamber depth and white-to-white measurements: a thorough literature review

2016

We have reviewed a set of recently published studies that compared the anterior chamber depth (ACD) and/or white-to-white (WTW) distance obtained by means of different measuring devices. Since some of those studies reached contradictory conclusions regarding device interchangeability, this review was carried out in attempting to clarify which clinical devices can or cannot be considered as interchangeable in clinical practice to measure ACD and/or WTW distance, among these devices: A-scan, ultrasound biomicroscopy, Orbscan and Orbscan II (Bausch&Lomb Surgical Inc., San Dimas, California, USA), Pentacam and Pentacam HR (Oculus, Wetzlar, Germany), Galilei (Ziemer, Switzerland), Visante optica…

White to whitemedicine.medical_specialtybusiness.industryReviewClinical Practice03 medical and health sciencesOphthalmologyAlcon LaboratoriesAnterior chamber eye0302 clinical medicineOphthalmology030221 ophthalmology & optometryMedicineOptometryOrbscan iiPentacam hrbusiness030217 neurology & neurosurgeryInternational Journal of Ophthalmology
researchProduct